WQ Series Submersible Sewage Pump
A submersible sewage centrifugal pump that works underwater without a pump house, covering 8-10000 m³/h at heads of 6-60 m with motor power from 0.75 kW to 280 kW.





The WQ series is a submersible sewage centrifugal pump designed for waste, sewage, rainwater, clean water and corrosive media that carry solid particles. Published coverage is 8-10000 m³/h at heads of 6-60 m with motor power from 0.75 kW to 280 kW, and the pump can run submerged without a pump house. A special large-channel design raises the drainage capacity so the pump passes solid particles whose diameter is about 50% of the pump port size. The mechanical seal uses hard, corrosion-resistant titanium-tungsten material, which the supplier states allows continuous running beyond 8000 hours. A double-rail auto-coupling mounting system and an automatic control cabinet can be specified, so the pump can be lifted out for service without anyone entering the wet well.
| Parameter | Specification |
| Flow rate | 8-10000 m³/h |
| Head | 6-60 m |
| Motor power | 0.75-280 kW |
| Pump type | Submersible sewage centrifugal |
| Speed | 2900 r/min (published models) |
| Solids handling | Passes particles of about 50% of the pump port diameter |
| Shaft seal | Titanium-tungsten mechanical seal, corrosion and wear resistant |
| Mounting option | Double-rail auto-coupling system for installation without entering the wet well |
| Control option | Automatic control cabinet with leakage, electric leakage, overload and over-temperature protection |
The table lists the published WQ models with outlet size, capacity, head, speed, motor power and efficiency. Larger sizes extend the series up to 10000 m³/h and 280 kW.
| Model | Outlet (mm) | Capacity (m³/h) | Head (m) | Speed (r/min) | Power (kW) | Efficiency (%) |
| 25WQ7-8-0.55 | 25 | 7 | 8 | 2900 | 0.55 | 45 |
| 25WQ8-25-1.1 | 25 | 8 | 25 | 2900 | 1.1 | 45 |
| 32WQ8-12-0.75 | 32 | 8 | 12 | 2900 | 0.75 | 48 |
| 40WQ12-15-1.5 | 40 | 12 | 15 | 2900 | 1.5 | 48 |
| 50WQ20-7-0.75 | 50 | 20 | 7 | 2900 | 0.75 | 62 |
| 50WQ10-10-0.75 | 50 | 10 | 10 | 2900 | 0.75 | 54 |
| 50WQ20-15-1.5 | 50 | 20 | 15 | 2900 | 1.5 | 51 |
| 50WQ15-30-2.2 | 50 | 15 | 30 | 2900 | 2.2 | 51 |
| 50WQ17-25-3 | 50 | 17 | 25 | 2900 | 3 | 53 |
| 50WQ25-32-5.5 | 50 | 25 | 32 | 2900 | 5.5 | 49 |
| 65WQ25-15-2.2 | 65 | 25 | 15 | 2900 | 2.2 | 52 |
| 65WQ37-13-3 | 65 | 37 | 13 | 2900 | 3 | 60 |
| 65WQ25-30-4 | 65 | 25 | 30 | 2900 | 4 | 58 |
| Item | Detail |
| Shaft seal | Titanium-tungsten mechanical seal, hard and corrosion resistant, for long continuous running |
| Impeller and channel | Special large-channel design that passes solids up to about 50% of the port diameter |
| Drive | Integral submersible motor, so no pump house or dry installation is needed |
| Mounting | Double-rail auto-coupling system available for guided installation and lifting |
| Control | Automatic control cabinet available for leakage, electric leakage, overload and over-temperature protection |
| Running position | Designed to work underwater, with compact structure and low noise |
- Sewage treatment plants: Moves raw sewage, sludge and return flows between process stages.
- Basements and civil defence: Drains basements, car parks and civil defence stations.
- Municipal engineering: Handles storm water and sewage in public drainage networks.
- Factories and hospitals: Empties process wastewater and sanitary drainage from buildings.
- Construction sites and mines: Dewaters pits carrying silt, stones and other debris.
- Farms and irrigation: Moves silty water for rural irrigation and drainage duties.
- Check the maximum particle size in the liquid against the published rule that solids may reach about 50% of the port diameter.
- Confirm the required head falls inside the 6-60 m range, and allow for the friction loss in a long discharge hose or pipe.
- Decide whether the installation needs the double-rail auto-coupling system, so the pump can be serviced without entering the wet well.
- Specify an automatic control cabinet if the pump has to run unattended with protection against leakage, overload and over-temperature.
- State whether the pumped liquid is corrosive, because corrosion resistance is a material selection matter rather than a standard feature.
What size of solids can a WQ submersible pump pass?
The special large-channel design lets the pump pass solid particles whose diameter is about 50% of the pump port size, so a 50 mm outlet model passes particles of roughly 25 mm.
Does a WQ pump need a pump house?
No. The pump is designed to work underwater, so it can be installed directly in the wet well with no pump house or dry chamber needed.
How is a WQ pump serviced if it sits in a sump?
A double-rail auto-coupling mounting system can be fitted, which allows the pump to be raised and reinstalled along guide rails without anyone entering the sewage pit.
What is the WQ series submersible pump used for?
Sewage treatment plants, basements and civil defence drainage, municipal engineering, factories, hospitals, construction sites, farms, mining and water treatment equipment support.
What flow and head does the WQ series cover?
Flow from 8 to 10000 m³/h and heads of 6-60 m, with motor power from 0.75 kW to 280 kW.
Which seal does the WQ pump use?
A titanium-tungsten mechanical seal. The supplier states this hard, corrosion-resistant material allows continuous running of more than 8000 hours.
Can the WQ pump run unattended?
Yes. An automatic control cabinet can be supplied with protection against water leakage, electric leakage, overload and over-temperature.
What should I send for a WQ pump selection?
Flow, head, liquid type and corrosiveness, maximum particle size, installation depth, voltage and frequency, and whether auto-coupling or a control cabinet is needed.
Related Products
- ZW Series Self-Priming Wastewater Pump
- HW Series Horizontal Mixed Flow Pump
- ZX Series Self-Priming Centrifugal Pump
- WFB Series Self-Priming Pump
- IS Series End-Suction Centrifugal Pump
How to Choose the Right WQ Series Submersible Sewage Pump
Quick answer: The WQ Series Submersible Sewage Pump covers flow 8-10000 m³/h, heads of 6-60 m, motor power 0.75-280 kW. Selection starts from the duty point - flow, head, liquid properties and available NPSH - rather than from the catalogue maxima.
Industry Applications
Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.