CDLF Series Multistage Centrifugal Pump
A vertical multistage centrifugal pump for thin, clean liquids from tap water to mildly corrosive industrial media, with 2-162 m³/h, heads of 36-200 m and 1.1-132 kW.





The CDLF series is a vertical multistage centrifugal pump for thin, clean, non-flammable and non-explosive liquids that carry no solid particles or fibres. Its working span runs from tap water through to mildly corrosive industrial liquids, with published coverage of 2-162 m³/h at heads of 36-200 m and motor ratings of 1.1-132 kW. The overflow section is produced from stainless steel plate by stamping and welding, and the shaft seal uses hard alloy and fluororubber mechanical seal elements, which is what extends the pump into mildly corrosive service. The inlet and outlet sit on the same horizontal plane as the pump base, so the pump can be built directly into a pipeline run without an elbow set. A standard motor drives the pump shaft through a coupling, and an intelligent protector can be specified to guard against dry running, phase loss and overload.
| Parameter | Specification |
| Flow rate | 2-162 m³/h |
| Head | 36-200 m |
| Motor power | 1.1-132 kW |
| Pump type | Vertical multistage centrifugal |
| Media | Thin, clean, non-flammable liquids from tap water to mildly corrosive industrial liquids |
| Overflow parts | Stainless steel plate, stamped and welded |
| Shaft seal | Mechanical seal, hard alloy and fluororubber |
| Ports | Inlet and outlet on the same horizontal plane as the pump base |
| Protection option | Intelligent protector against dry running, phase loss and overload |
The supplier publishes one parameter table for the CDL and CDLF family, giving head at eight flow points per model. The rows below show the rated duty point at 2 m³/h for each model in the published range.
| Model | Flow (m³/h) | Head (m) | Power (kW) |
| CDL2.2 | 2 | 15 | 0.37 |
| CDL2.3 | 2 | 22 | 0.37 |
| CDL2.4 | 2 | 30 | 0.55 |
| CDL2.5 | 2 | 37 | 0.55 |
| CDL2.6 | 2 | 45 | 0.75 |
| CDL2.7 | 2 | 52 | 0.75 |
| CDL2.9 | 2 | 67 | 1.1 |
| CDL2.11 | 2 | 82 | 1.1 |
| CDL2.13 | 2 | 98 | 1.5 |
| CDL2.15 | 2 | 112 | 1.5 |
| CDL2.18 | 2 | 136 | 2.2 |
| CDL2.22 | 2 | 165 | 2.2 |
| CDL2.26 | 2 | 198 | 2.2 |
| Item | Detail |
| Overflow section | Stainless steel plate formed by stamping and welding, suitable for mildly corrosive media |
| Shaft seal | Mechanical seal with hard alloy and fluororubber elements |
| Motor | Standard motor, output shaft coupled directly to the pump shaft |
| Protection | Intelligent protector available for dry running, phase loss and overload |
| Cylinder assembly | Pressure-resistant cylinder and impeller assembly bolted between pump head and inlet and outlet sections |
| Ports | Same-plane inlet and outlet for simple pipeline installation |
- Reverse osmosis plants: Feeds RO membranes and ultrafiltration skids where the feed is thin and low in solids.
- Water supply systems: Plant filtration and delivery, zoned supply and high-rise pressure boosting.
- Industrial pressure boosting: Process water, cleaning and high-pressure washing systems.
- Distillation and treatment plant: Circulation and transfer duty on clean or mildly corrosive process water.
- HVAC and boiler systems: Cooling circuits, boiler feed water and condensate transfer.
- Irrigation systems: Sprinkler and drip irrigation where mild chemical addition is present.
- Check the medium against the published envelope: thin, clean and non-flammable, without solid particles or fibres.
- Where the liquid is mildly corrosive, confirm the stainless steel overflow parts and the hard alloy and fluororubber seal are adequate for the concentration involved.
- Read the eight-point head curve for the chosen model so the duty point sits inside the stable part of the curve.
- Provide a flooded suction or adequate NPSH margin, as the series is not self-priming.
- Decide whether the intelligent protector is required to cover dry running, phase loss and overload.
What makes the CDLF pump different from the CDL pump?
The CDLF series is specified for media from tap water through to mildly corrosive industrial liquids. It uses the same stainless steel overflow section and hard alloy, fluororubber mechanical seal, so it extends the family into mildly aggressive duty.
Can a CDLF pump be used on a reverse osmosis system?
Yes. Reverse osmosis and ultrafiltration duty is listed among the intended applications, provided the feed is thin and clean as published, and the duty point is taken from the head curve.
How do I choose between models in the CDLF range?
Start with the flow and head you need, then compare that point with the published head curve. Model numbers such as CDL2.2 to CDL2.26 indicate the number of stages, and more stages mean more head at the same flow.
What liquids can the CDLF series pump handle?
Thin, clean, non-flammable and non-explosive liquids without solid particles or fibres, ranging from tap water to mildly corrosive industrial liquids.
What flow and head does the CDLF series cover?
The published range is 2-162 m³/h at heads of 36-200 m, with motor power from 1.1 kW to 132 kW.
Can the CDLF pump handle corrosive media?
It is intended for mildly corrosive media. The overflow section is stainless steel and the seal uses hard alloy and fluororubber, so confirm the concentration and temperature of your liquid before selection.
Does the CDLF pump need priming?
It is not self-priming, so a flooded suction or a priming arrangement is required. It is normally installed in a pipeline with a positive inlet head.
What information is needed for a CDLF pump quote?
Flow, head, liquid name, concentration and temperature, available NPSH, voltage and frequency, and any requirement for an intelligent protector.
Related Products
- CDL Series Vertical Multistage Centrifugal Pump
- GC Series Multistage Boiler Feed Water Pump
- D Series High Head Centrifugal Pump
- MD Series Horizontal Multistage Centrifugal Pump
- IS Series End-Suction Centrifugal Pump
How to Choose the Right CDLF Series Multistage Centrifugal Pump
Quick answer: The CDLF Series Multistage Centrifugal Pump covers flow 2-162 m³/h, heads of 36-200 m, motor power 1.1-132 kW. Selection starts from the duty point - flow, head, liquid properties and available NPSH - rather than from the catalogue maxima.
Industry Applications
Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.