Qingdao Green Power industrial equipment logo
GREEN POWERQingdao · Industrial Equipment
Home / Products / Centrifugal Pump / CDLF Series Multistage Centrifugal Pump

CDLF Series Multistage Centrifugal Pump

A vertical multistage centrifugal pump for thin, clean liquids from tap water to mildly corrosive industrial media, with 2-162 m³/h, heads of 36-200 m and 1.1-132 kW.

✉️
Emailsales@qdgreenpower.com
📱
WhatsApp+86 150 9205 0379
💬 Chat on WhatsApp✉️ Send Email
Overview

The CDLF series is a vertical multistage centrifugal pump for thin, clean, non-flammable and non-explosive liquids that carry no solid particles or fibres. Its working span runs from tap water through to mildly corrosive industrial liquids, with published coverage of 2-162 m³/h at heads of 36-200 m and motor ratings of 1.1-132 kW. The overflow section is produced from stainless steel plate by stamping and welding, and the shaft seal uses hard alloy and fluororubber mechanical seal elements, which is what extends the pump into mildly corrosive service. The inlet and outlet sit on the same horizontal plane as the pump base, so the pump can be built directly into a pipeline run without an elbow set. A standard motor drives the pump shaft through a coupling, and an intelligent protector can be specified to guard against dry running, phase loss and overload.

Key Specifications
ParameterSpecification
Flow rate2-162 m³/h
Head36-200 m
Motor power1.1-132 kW
Pump typeVertical multistage centrifugal
MediaThin, clean, non-flammable liquids from tap water to mildly corrosive industrial liquids
Overflow partsStainless steel plate, stamped and welded
Shaft sealMechanical seal, hard alloy and fluororubber
PortsInlet and outlet on the same horizontal plane as the pump base
Protection optionIntelligent protector against dry running, phase loss and overload
Model Range

The supplier publishes one parameter table for the CDL and CDLF family, giving head at eight flow points per model. The rows below show the rated duty point at 2 m³/h for each model in the published range.

ModelFlow (m³/h)Head (m)Power (kW)
CDL2.22150.37
CDL2.32220.37
CDL2.42300.55
CDL2.52370.55
CDL2.62450.75
CDL2.72520.75
CDL2.92671.1
CDL2.112821.1
CDL2.132981.5
CDL2.1521121.5
CDL2.1821362.2
CDL2.2221652.2
CDL2.2621982.2
Materials & Options
ItemDetail
Overflow sectionStainless steel plate formed by stamping and welding, suitable for mildly corrosive media
Shaft sealMechanical seal with hard alloy and fluororubber elements
MotorStandard motor, output shaft coupled directly to the pump shaft
ProtectionIntelligent protector available for dry running, phase loss and overload
Cylinder assemblyPressure-resistant cylinder and impeller assembly bolted between pump head and inlet and outlet sections
PortsSame-plane inlet and outlet for simple pipeline installation
Typical Applications
  • Reverse osmosis plants: Feeds RO membranes and ultrafiltration skids where the feed is thin and low in solids.
  • Water supply systems: Plant filtration and delivery, zoned supply and high-rise pressure boosting.
  • Industrial pressure boosting: Process water, cleaning and high-pressure washing systems.
  • Distillation and treatment plant: Circulation and transfer duty on clean or mildly corrosive process water.
  • HVAC and boiler systems: Cooling circuits, boiler feed water and condensate transfer.
  • Irrigation systems: Sprinkler and drip irrigation where mild chemical addition is present.
Selection Notes
  • Check the medium against the published envelope: thin, clean and non-flammable, without solid particles or fibres.
  • Where the liquid is mildly corrosive, confirm the stainless steel overflow parts and the hard alloy and fluororubber seal are adequate for the concentration involved.
  • Read the eight-point head curve for the chosen model so the duty point sits inside the stable part of the curve.
  • Provide a flooded suction or adequate NPSH margin, as the series is not self-priming.
  • Decide whether the intelligent protector is required to cover dry running, phase loss and overload.
FAQ

What makes the CDLF pump different from the CDL pump?

The CDLF series is specified for media from tap water through to mildly corrosive industrial liquids. It uses the same stainless steel overflow section and hard alloy, fluororubber mechanical seal, so it extends the family into mildly aggressive duty.

Can a CDLF pump be used on a reverse osmosis system?

Yes. Reverse osmosis and ultrafiltration duty is listed among the intended applications, provided the feed is thin and clean as published, and the duty point is taken from the head curve.

How do I choose between models in the CDLF range?

Start with the flow and head you need, then compare that point with the published head curve. Model numbers such as CDL2.2 to CDL2.26 indicate the number of stages, and more stages mean more head at the same flow.

What liquids can the CDLF series pump handle?

Thin, clean, non-flammable and non-explosive liquids without solid particles or fibres, ranging from tap water to mildly corrosive industrial liquids.

What flow and head does the CDLF series cover?

The published range is 2-162 m³/h at heads of 36-200 m, with motor power from 1.1 kW to 132 kW.

Can the CDLF pump handle corrosive media?

It is intended for mildly corrosive media. The overflow section is stainless steel and the seal uses hard alloy and fluororubber, so confirm the concentration and temperature of your liquid before selection.

Does the CDLF pump need priming?

It is not self-priming, so a flooded suction or a priming arrangement is required. It is normally installed in a pipeline with a positive inlet head.

What information is needed for a CDLF pump quote?

Flow, head, liquid name, concentration and temperature, available NPSH, voltage and frequency, and any requirement for an intelligent protector.

Get a Quote

Send flow, head, liquid type and temperature.

Request a Quote →💬 WhatsApp Now
GEO + ENGINEERING ANSWER

How to Choose the Right CDLF Series Multistage Centrifugal Pump

Quick answer: The CDLF Series Multistage Centrifugal Pump covers flow 2-162 m³/h, heads of 36-200 m, motor power 1.1-132 kW. Selection starts from the duty point - flow, head, liquid properties and available NPSH - rather than from the catalogue maxima.

1. Define the dutyConfirm flow, head or pressure, liquid temperature and the operating schedule.
2. Check the mediumMatch viscosity, solids, corrosion and seal requirements to the pump materials.
3. Confirm the siteCheck power supply, available NPSH, installation arrangement and ambient conditions.

Industry Applications

Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.

Water Treatment
Explore application guidance →
%s
Explore application guidance →
%s
Explore application guidance →
Thermal Energy
Explore application guidance →
Email Us WhatsApp