CDL Series Vertical Multistage Centrifugal Pump
A vertical multistage centrifugal pump for clean water and pressure boosting, with published coverage of 2-162 m³/h, heads of 36-200 m and motor power from 1.1 kW to 132 kW.





The CDL series is a vertical, non-self-priming multistage centrifugal pump for clean, non-flammable media that contain no solid particles or fibres. Published coverage is 2-162 m³/h at heads of 36-200 m with motor ratings of 1.1-132 kW, which suits water supply, industrial pressure boosting, water treatment and farmland irrigation. The pressure-retaining cylinder and impeller assembly are clamped between the pump head and the inlet and outlet sections, and the ports sit on the same horizontal plane as the base, so the unit drops straight into a pipeline. The overflow section is fabricated from stainless steel plate by stamping and welding, which makes the pump suitable for mildly corrosive media. The shaft seal is a cartridge mechanical seal with hard alloy and fluororubber elements, and an intelligent protector can be fitted to guard against dry running, phase loss and overload.
| Parameter | Specification |
| Flow rate | 2-162 m³/h |
| Head | 36-200 m |
| Motor power | 1.1-132 kW |
| Pump type | Vertical multistage centrifugal, non-self-priming |
| Overflow parts | Stainless steel plate, stamped and welded |
| Shaft seal | Mechanical seal, hard alloy and fluororubber |
| Drive | Standard motor, output shaft coupled directly to the pump shaft |
| Ports | Inlet and outlet on the same horizontal plane as the pump base |
| Protection option | Intelligent protector against dry running, phase loss and overload |
The published parameter table gives head at eight flow points for each model. The table below shows the rated duty point of each published model in the CDL2 range; heads are listed at 2 m³/h.
| Model | Flow (m³/h) | Head (m) | Power (kW) |
| CDL2.2 | 2 | 15 | 0.37 |
| CDL2.3 | 2 | 22 | 0.37 |
| CDL2.4 | 2 | 30 | 0.55 |
| CDL2.5 | 2 | 37 | 0.55 |
| CDL2.6 | 2 | 45 | 0.75 |
| CDL2.7 | 2 | 52 | 0.75 |
| CDL2.9 | 2 | 67 | 1.1 |
| CDL2.11 | 2 | 82 | 1.1 |
| CDL2.13 | 2 | 98 | 1.5 |
| CDL2.15 | 2 | 112 | 1.5 |
| CDL2.18 | 2 | 136 | 2.2 |
| CDL2.22 | 2 | 165 | 2.2 |
| CDL2.26 | 2 | 198 | 2.2 |
| Item | Detail |
| Casing and overflow section | Stainless steel plate, formed by stamping and welding |
| Shaft seal | Mechanical seal with hard alloy and fluororubber elements |
| Motor | Standard motor with the output shaft coupled directly to the pump shaft; users can fit their own motor where preferred |
| Protection | Intelligent protector available for dry running, phase loss and overload protection |
| Installation | Pressure cylinder and impeller assembly clamped by bolts between the pump head and the inlet and outlet sections |
| Ports | Inlet and outlet on the same plane as the pump seat for direct pipeline mounting |
- Water supply systems: Plant filtration and delivery, zoned distribution and high-rise pressure boosting.
- Industrial pressure boosting: Process water systems, cleaning lines, high-pressure washing and fire protection systems.
- Water treatment: Ultrafiltration, reverse osmosis, distillation and swimming pool treatment plants.
- HVAC and boiler plant: Cooling and air-conditioning circuits, boiler feed water and condensate systems.
- Farmland irrigation: Sprinkler and drip irrigation fed from tanks, wells or storage ponds.
- Machine tool and process support: Auxiliary water and mildly corrosive media transfer inside plants.
- Build the duty from flow and head together, then read the corresponding point on the eight-point head curve for your chosen model.
- Confirm the medium is thin and clean; abrasive solids, fibres and flammable liquids are outside the published duty.
- Choose the stainless steel construction where the liquid is mildly corrosive, and confirm the seal materials against the medium.
- Check the available NPSH at the suction, because the series is not self-priming and needs a positive inlet condition.
- Decide whether the pump will use the standard coupled motor or a motor of your own, and whether an intelligent protector is required.
How much head can a CDL vertical multistage pump reach?
The series covers 36-200 m in total, and individual models within the CDL2 range reach from 15 m on CDL2.2 up to 198 m on CDL2.26 at 2 m³/h. Head rises with the number of stages in the pump.
Is the CDL pump self-priming?
No. The CDL series is a non-self-priming multistage pump, so it needs a flooded suction or a separate priming arrangement. Where suction lift is unavoidable, use a self-priming series.
Can a CDL pump be used for mildly corrosive liquids?
Yes. The overflow section is made from stamped and welded stainless steel plate and the seal uses hard alloy and fluororubber elements, which is what makes the pump suitable for mildly corrosive media.
What is the CDL series pump used for?
It handles clean, non-flammable media without solid particles or fibres in water supply, industrial pressure boosting, water treatment and farmland irrigation.
What flow and head does the CDL series cover?
The published range is 2-162 m³/h at heads of 36-200 m with motor power from 1.1 kW to 132 kW.
Which seal does the CDL pump use?
A stainless steel cartridge mechanical seal with hard alloy and fluororubber elements, which the supplier states improves running reliability and raises the permissible medium temperature.
Can the CDL pump be supplied with dry-run protection?
Yes. An intelligent protector can be fitted to prevent damage from dry running, phase loss and overload.
What should I send for a CDL pump quotation?
Flow, head, liquid name and temperature, available NPSH, motor voltage and frequency, and whether an intelligent protector is needed.
Related Products
- ISW Series Horizontal Inline Centrifugal Pump
- IS Series End-Suction Centrifugal Pump
- Pipeline Circulation Pump
How to Choose the Right CDL Series Vertical Multistage Centrifugal Pump
Quick answer: The CDL Series Vertical Multistage Centrifugal Pump covers flow 2-162 m³/h, heads of 36-200 m, motor power 1.1-132 kW. Selection starts from the duty point - flow, head, liquid properties and available NPSH - rather than from the catalogue maxima.
Industry Applications
Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.