Qingdao Green Power industrial equipment logo
GREEN POWERQingdao · Industrial Equipment
Home / Products / Centrifugal Pump / GC Series Multistage Boiler Feed Water Pump

GC Series Multistage Boiler Feed Water Pump

A horizontal single-suction multistage sectional pump for boiler feed and clear water duty, with capacity from 6 to 110 m³/h, heads of 46-570 m and power from 3 to 110 kW.

✉️
Emailsales@qdgreenpower.com
📱
WhatsApp+86 150 9205 0379
💬 Chat on WhatsApp✉️ Send Email
Overview

The GC series is a horizontal, single-suction, multistage sectional centrifugal pump for clear water below 110°C and for other non-corrosive liquids with properties similar to water. Published coverage is 6-110 m³/h at heads of 46-570 m with motor ratings of 3-110 kW, which places it in small boiler feed, hot water circulation, pressure vessel supply and high-rise building supply. Head is produced by stacking stages, so the same sectional design covers a wide pressure range from a compact casing. The shaft seal is soft packing, which keeps the structure simple and makes maintenance quick and safe. The pump runs smoothly with low pulsation and low noise, and the supplier also lists it for garden irrigation, fire boosting, food, brewing, medicine and chemical service.

Key Specifications
ParameterSpecification
Capacity6-110 m³/h
Head46-570 m
Motor power3-110 kW
Pump typeHorizontal, single-suction, multistage sectional
Liquid temperatureBelow 110°C for clear water
Shaft sealSoft packing seal
MediaClear water and non-corrosive liquids with properties similar to water
Running characteristicsSmooth operation, stable delivery, small pulsation
Typical dutySmall boiler feed water and hot water circulation
Model Range

The table lists the published GC models with their rated capacity, head and motor power. Model numbers carry the stage count after the asterisk, so 5GC-8*3 is a three-stage build of the 5GC-8 casing.

ModelCapacity (m³/h)Head (m)Power (kW)
1.5GC-5*26463
1.5GC-5*36694
1.5GC-5*46925.5
2GC-5*210647.5
2GC-5*3109611
2GC-5*41012815
2.5GC-6*215627.5
2.5GC-6*3159311
2.5GC-6*41512415
4GC-8*2308622
4GC-8*33012930
4GC-8*43017245
5GC-8*27213855
5GC-8*2A7212255
5GC-8*2B7211745
Materials & Options
ItemDetail
Shaft sealSoft packing seal, simple to maintain and quick to renew
CasingHorizontal sectional multistage body with single suction
Hydraulic designAdvanced hydraulic model giving high efficiency over a wide performance range
RotorMultistage rotor carried in the sectional casing
DriveCoupled electric motor
Media limitsClear water below 110°C and non-corrosive liquids similar to water
Typical Applications
  • Small boiler feed: The primary duty - feeding water to small industrial and heating boilers.
  • Hot water circulation: Circulates hot water in heating and process loops.
  • Pressure vessel supply: Feeds water into pressure vessels and closed circuits.
  • High-rise building supply: Boosts water to elevated tanks and tall buildings.
  • Farmland irrigation and fire boosting: Raises water for irrigation and fire main pressure.
  • Process industries: Serves food, brewing, medicine, chemical, aquaculture and environmental plant.
Selection Notes
  • Read the model number as casing plus stage count, because the stage count sets the head for a given capacity.
  • Confirm the water is clear and below 110°C; the series is not intended for solids or corrosive media.
  • Compare the published motor power with the duty point, since the table lists one rating for each stage build.
  • Plan for packing maintenance, because a soft packing seal needs periodic adjustment and renewal.
  • Check the NPSH available at the suction, particularly where hot water is being fed to a boiler.
FAQ

How do I pick a GC model for boiler feed duty?

Match the boiler feed rate to the capacity column, then choose the stage count that delivers the required boiler pressure. For example 1.5GC-5*2 gives 6 m³/h at 46 m, while 1.5GC-5*4 gives the same flow at 92 m.

What is the maximum head of the GC series?

The published range runs to 570 m, with capacity from 6 to 110 m³/h and motor power from 3 kW to 110 kW.

Which shaft seal does the GC pump use?

A soft packing seal. It is safe and reliable, structurally simple and quick to maintain compared with more complex seal arrangements.

What is the GC series pump used for?

Small boiler feed water is the main duty, together with hot water circulation, pressure vessel supply, high-rise building supply, irrigation, fire boosting and process water in food, brewing, medicine and chemical plants.

What capacity and head does the GC series cover?

Capacity from 6 to 110 m³/h and heads of 46-570 m, with motor power from 3 kW to 110 kW.

What temperature can the GC pump handle?

Clear water below 110°C and other non-corrosive liquids with physical and chemical properties similar to water.

Which seal does the GC pump use?

A soft packing shaft seal, which the supplier states is safe, reliable, simple and quick to maintain.

How do I quote a GC pump?

Send the feed rate, boiler or system pressure in metres of head, water temperature, available NPSH, voltage and frequency.

Get a Quote

Send flow, head, liquid type and temperature.

Request a Quote →💬 WhatsApp Now
GEO + ENGINEERING ANSWER

How to Choose the Right GC Series Multistage Boiler Feed Water Pump

Quick answer: The GC Series Multistage Boiler Feed Water Pump covers capacity 6-110 m³/h, heads of 46-570 m, motor power 3-110 kW. Selection starts from the duty point - flow, head, liquid properties and available NPSH - rather than from the catalogue maxima.

1. Define the dutyConfirm flow, head or pressure, liquid temperature and the operating schedule.
2. Check the mediumMatch viscosity, solids, corrosion and seal requirements to the pump materials.
3. Confirm the siteCheck power supply, available NPSH, installation arrangement and ambient conditions.

Industry Applications

Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.

Water Treatment
Explore application guidance →
Chemical & Petrochemical
Explore application guidance →
Food & Beverage
Explore application guidance →
Thermal Energy
Explore application guidance →

Technical selection & RFQ

Request a Quote for GC Series Multistage Boiler Feed Water Pump

Looking for a GC Series Multistage Boiler Feed Water Pump supplier for an industrial project? Share the operating conditions below so our team can review the duty, recommend a suitable configuration and prepare a quotation. Final model selection and performance should be confirmed against your actual process conditions and the applicable product data.

Information to include in your inquiry

  • Duty point: Required flow rate and total head / discharge pressure; include the operating point if known
  • Pumped medium: Fluid name, concentration, viscosity, density, solids content and corrosiveness
  • Operating conditions: Normal and maximum temperature, inlet pressure, suction lift and duty cycle
  • Materials & sealing: Preferred wetted materials, seal type and any leakage or hygiene requirements
  • Motor & installation: Voltage, frequency, phase, hazardous-area requirements if applicable, and mounting / connection details

Not all details are available yet? Send the information you have, your datasheet or a process description. We can identify the missing selection data before confirming a model.

Email for a Quotation Discuss Requirements on WhatsApp
Email Us WhatsApp