IHF Series PTFE-Lined Chemical Pump
A single-stage fluoroplastic-lined centrifugal pump for strong acids, alkalis and oxidising media, covering 3.5–300 m³/h and heads of 4.5–87 m at −20 °C to 100 °C.





The IHF series is a single-stage, single-suction centrifugal pump whose wetted surfaces are lined with fluoroplastic so that aggressive media only contact plastic rather than bare metal. The published working envelope is 3.5–300 m³/h of flow, 4.5–87 m of head and a medium temperature of −20 °C to 100 °C.
The pump body is a metal casing lined with PTFE, while the pump cover, impeller and liner plate are made by sintering and pressing fluoroplastic onto metal inserts. The shaft seal is an externally mounted bellows mechanical seal: the stationary ring is 99.9 % alumina ceramic or silicon nitride and the rotating ring uses a PTFE filling material, with SSIC industrial ceramics also published for the seal faces.
Because the wetted path is a plastic lining rather than a solid plastic moulding, the pump keeps metal-casing strength while handling any concentration of sulphuric, nitric, hydrochloric, hydrofluoric and acetic acid, strong alkalis, strong oxidising agents and organic solvents. It is applied in chemical, metallurgical, pesticide, pharmaceutical, printing-and-dyeing and paper-making plants, in non-ferrous metal smelting, in acid baths in automotive manufacturing and in waste-water treatment.
| Parameter | Specification |
| Pump type | Single-stage, single-suction centrifugal pump with fluoroplastic lining |
| Flow rate | 3.5–300 m³/h |
| Head | 4.5–87 m |
| Medium temperature | −20 °C to 100 °C |
| Pump body | Metal casing lined with PTFE fluoroplastic |
| Cover, impeller, liner plate | Metal inserts with sintered and pressed fluoroplastic |
| Shaft seal | Externally mounted bellows mechanical seal |
| Stationary ring | 99.9 % alumina ceramic or silicon nitride |
| Rotating ring | PTFE filling material; SSIC industrial ceramics also published |
| Media | Strong acids, alkalis, oxidising agents and organic solvents |
| Model | Inlet (mm) | Outlet (mm) | Flow (m³/h) | Head (m) | Motor (kW) |
| IHF50-32-125 | 50 | 32 | 12.5 | 20 | 2.2 |
| IHF50-32-125A | 50 | 32 | 11 | 16 | 1.5 |
| IHF50-32-160 | 50 | 32 | 12.5 | 32 | 4 |
| IHF50-32-160A | 50 | 32 | 11.7 | 28 | 3 |
| IHF50-32-200 | 50 | 32 | 12.5 | 50 | 7.5 |
| IHF50-32-200A | 50 | 32 | 11.7 | 44 | 5.5 |
| IHF65-50-125 | 65 | 50 | 25 | 20 | 3 |
| IHF65-50-125A | 65 | 50 | 22.3 | 16 | 2.2 |
| IHF65-50-160 | 65 | 50 | 25 | 32 | 5.5 |
| IHF65-50-160A | 65 | 50 | 23.4 | 28 | 4 |
| IHF65-40-200 | 65 | 40 | 25 | 50 | 11 |
| IHF65-40-200A | 65 | 40 | 23.4 | 44 | 7.5 |
| IHF80-65-125 | 80 | 65 | 50 | 20 | 5.5 |
| IHF80-65-125A | 80 | 65 | 45 | 16 | 4 |
Duty points as published by the manufacturer; the A suffix denotes the trimmed-impeller variant of the same casing. Additional sizes and trims are quoted on request.
| Item | Published option |
| Casing lining | PTFE fluoroplastic lining on a metal casing |
| Pump cover | Metal insert with sintered and pressed fluoroplastic |
| Impeller | Fluoroplastic alloy formed on a metal insert with dedicated moulds |
| Liner plate | Metal insert with sintered and pressed fluoroplastic |
| Shaft seal | Externally mounted bellows mechanical seal |
| Static seal ring | 99.9 % alumina ceramic, or silicon nitride |
| Dynamic seal ring | PTFE filling material; SSIC industrial ceramics as an alternative |
| Media coverage | Sulphuric, nitric, hydrochloric, hydrofluoric and acetic acid; strong alkali; strong oxidising agents; organic solvents |
- Acid transfer in chemical plants: Moves strong acids and acid mixtures where a fluoroplastic lining is required.
- Non-ferrous metal smelting: Handles corrosive media and electrolytes in smelting and refining lines.
- Automotive manufacturing: Serves acid-bath and surface-treatment circuits in vehicle production.
- Pesticide manufacturing: Transfers aggressive intermediates and formulations in pesticide plants.
- Waste-water treatment: Pumps corrosive chemical waste streams in treatment works.
- Printing and dyeing: Circulates corrosive dye liquors and treatment chemicals in textile plants.
- Pharmaceutical and paper: Moves corrosive process liquids where metal contact must be avoided.
- Confirm the medium against the published lining coverage before selecting the size, since the lining protects the hydraulic path but not the seal faces.
- Keep the working temperature inside the published −20 °C to 100 °C window; the bellows seal and the lining are both temperature-limited.
- Check the seal-face material against the medium: alumina ceramic is the standard published option, with silicon nitride and SSIC ceramics offered where abrasion or chemical attack requires them.
- Work from the duty point in the 3.5–300 m³/h and 4.5–87 m range, and prefer a trimmed impeller over throttling when the head is lower.
- State whether the medium contains abrasive particles, because that decides the seal-face and liner-plate material rather than the pump size.
- Verify the inlet and outlet sizes against the existing pipework using the published port table before ordering.
Which IHF model do I need for a given flow and head?
Match the duty point to the published model table: the IHF series spans 3.5–300 m³/h and 4.5–87 m. Models such as IHF50-32-200 and IHF65-40-200 cover the higher heads of 44–50 m, while IHF50-32-125 and IHF65-50-125 handle the lower heads at the same casing sizes.
Is the IHF pump suitable for hydrofluoric or nitric acid?
Yes. The published media coverage of the IHF series includes any concentration of sulphuric, nitric, hydrochloric, hydrofluoric and acetic acid, strong alkalis, strong oxidising agents and organic solvents, because the wetted path is fluoroplastic-lined.
What seal does the IHF pump use?
It uses an externally mounted bellows mechanical seal with a 99.9 % alumina ceramic or silicon nitride stationary ring and a PTFE-filled rotating ring; SSIC industrial ceramics are also published as a seal-face option.
Can the IHF pump be used above 100 °C?
The published medium temperature range is −20 °C to 100 °C. Operation outside that band needs to be checked with the manufacturer, since both the fluoroplastic lining and the bellows seal are temperature-limited.
What media can the IHF chemical pump handle?
Any concentration of sulphuric, nitric, hydrochloric, hydrofluoric and acetic acid, strong alkalis, strong oxidising agents and organic solvents, plus chemically similar electrolytes used in smelting and automotive acid baths.
What is the flow and head range of the IHF series?
Flow from 3.5 to 300 m³/h and heads from 4.5 to 87 m, over the 14 published model designations listed in the model table.
How are the wetted parts constructed?
The body is a metal casing lined with PTFE; the cover, impeller and liner plate are fluoroplastic sintered and pressed onto metal inserts, so the lining carries the corrosion duty while the metal carries the mechanical load.
What seal is fitted to the IHF pump?
An externally mounted bellows mechanical seal with a 99.9 % alumina ceramic or silicon nitride stationary ring and a PTFE-filled rotating ring; SSIC industrial ceramics are published as an alternative.
What temperature range does the IHF pump accept?
The published medium temperature range is −20 °C to 100 °C.
Related Products
- IH Series Stainless Steel Chemical Pump
- Chemical Pump (IH / IHF / IHG / FB-AFB / FSB / SFBX)
How to Select the Right IHF Lined Chemical Pump
Quick answer: Lined chemical pumps are selected from liquid aggressiveness, lining material, flow and head. PTFE, FEP or PFA protect the wetted parts.
Selection Data to Send Our Engineers
- Liquid name and concentration
- Lining requirement (PTFE / FEP / PFA)
- Flow rate
- Head / pressure
- Temperature
- Motor voltage, frequency and seal preference
Industry Applications
Explore how this equipment can be applied in related industrial sectors and review application-specific selection guidance.