IHG Series Vertical Inline Chemical Pump
A vertical inline centrifugal pump built to international standards for water supply and clear liquids, covering 1–1500 m³/h and heads of 7–150 m in a small footprint.





The IHG series is a vertical inline centrifugal pump manufactured to international standards and using an up-to-date hydraulic model, published with high efficiency and energy-saving characteristics. Its stated advantages are a small footprint, low construction investment, low noise and no pollution, which makes it a common choice for urban water supply, high-rise buildings and long-distance water supply.
The published performance envelope is 1–1500 m³/h of flow with heads from 7 to 150 m. Because the suction and discharge connections sit on a common centre line, the pump can be mounted directly in a straight pipe run, and the vertical arrangement removes the need for a long baseplate and coupling guard.
The pump is published for clear water and for other liquids whose physical and chemical properties are similar to those of clear water. For each model the manufacturer lists three duty points across the impeller range, so a single casing covers a band of flow and head rather than one fixed operating point.
| Parameter | Specification |
| Pump type | Vertical inline single-stage centrifugal pump |
| Design basis | Manufactured in accordance with international standards using an advanced hydraulic model |
| Flow rate | 1–1500 m³/h |
| Head | 7–150 m |
| Media | Clear water and liquids with physical and chemical properties similar to clear water |
| Installation | Vertical inline; suction and discharge on a common centre line |
| Published advantages | High efficiency and energy saving, small footprint, low construction investment, low noise, no pollution |
| Drive | Close-coupled electric motor at 2800–2900 r/min |
| Typical services | Urban water supply, high-rise buildings, long-distance water supply |
| Published data per model | Capacity, lift head, speed, motor power and inlet / outlet diameter |
| Model | Capacity (m³/h) | Head (m) | Speed (r/min) | Motor (kW) | Inlet / Outlet (mm) |
| 15-80 | 1.1 / 1.5 / 2.0 | 8.5 / 8 / 7 | 2800 | 0.18 | 15 |
| 20-110 | 1.8 / 2.5 / 3.3 | 16 / 15 / 13.5 | 2800 | 0.37 | 20 |
| 20-160 | 1.8 / 2.5 / 3.3 | 33 / 32 / 30 | 2900 | 0.75 | 20 |
| 25-110 | 2.8 / 4 / 5.2 | 16 / 15 / 13.5 | 2900 | 0.55 | 25 |
| 25-125 | 2.8 / 4 / 5.2 | 20.6 / 20 / 18 | 2900 | 0.75 | 25 |
| 25-125A | 2.5 / 3.6 / 4.6 | 17 / 16 / 14.4 | 2900 | 0.55 | 25 |
| 25-160 | 2.8 / 4 / 5.2 | 33 / 32 / 30 | 2900 | 1.5 | 25 |
| 25-160A | 2.6 / 3.7 / 4.9 | 29 / 28 / 26 | 2900 | 1.1 | 25 |
| 32-100 | 4.5 | 12.5 | 2900 | 0.55 | 32 |
| 32-100 (I) | 4.4 / 6.3 / 8.3 | 13.2 / 12.5 / 11.3 | 2900 | 0.75 | 32 |
| 32-125 | 3.5 / 5 / 6.5 | 22 / 20 / 18 | 2900 | 0.75 | 32 |
| 32-125A | 3.1 / 4.5 / 5.8 | 17.6 / 16 / 14.4 | 2900 | 0.55 | 32 |
| 32-160 | 6.5 | 32 | 2900 | 1.5 | 32 |
| 32-160A | 4 | 25 | 2900 | 1.1 | 32 |
| 32-160 (I) | 4.4 / 6.3 / 8.3 | 33.2 / 32 / 30.2 | 2900 | 2.2 | 32 |
Models as published by the manufacturer. Where three values are shown they are the three published duty points for that model, listed in the same order in the capacity and head columns. The A suffix marks the trimmed-impeller version and (I) the alternative impeller variant of the same casing.
| Item | Published option |
| Construction | Vertical inline single-stage centrifugal pump to international standards |
| Hydraulic model | Advanced hydraulic design published as high efficiency and energy saving |
| Installation | Inline ports on a common centre line, vertical motor above the casing |
| Medium | Clear water and liquids with physical and chemical properties similar to clear water |
| Speed | 2800 r/min on the smallest models, 2900 r/min on the remainder |
| Motor | Close-coupled electric motor, 0.18–2.2 kW in the published range; other supplies confirmed at order stage |
| Published per-model data | Capacity, lift head, speed, motor power and inlet / outlet diameter |
- Urban water supply: Boosts mains pressure in town and district water networks.
- High-rise buildings: Provides inline pressure boosting on upper floors and in riser systems.
- Long-distance water supply: Works in series as a booster station on long supply mains.
- Building services: Circulates heating, cooling and general service water in buildings.
- Industrial process water: Feeds clear process water to plants where no solids are present.
- Fire and utility systems: Serves clear-water utility circuits that need a compact inline unit.
- Irrigation: Supplies clean water to irrigation and distribution lines.
- Note that the published table lists three duty points per model: choose the point that matches the required flow and head rather than the largest figure in the row.
- Select from the published A and (I) variants when the duty point falls between two standard models, since they are the trimmed and alternative impellers of the same casing.
- Confirm the liquid is clear or has properties similar to clear water; the series is not published for sludges, slurries or aggressive chemical media.
- Use the 2800 rpm and 2900 rpm data separately, because the smallest sizes 15-80 and 20-110 are published at 2800 r/min.
- Check the inlet / outlet diameter column against the pipe run before ordering, since the inline body must match the existing line size.
- Allow for the vertical installation height in the plant layout; the inline arrangement saves floor area but needs headroom above the motor.
What does the model number of an IHG pump mean?
The two published figures describe the pump: the first is the nominal inlet and outlet size in millimetres and the second is the casing size, so 25-125 is a 25 mm inline pump with a 125 casing and 32-160 is a 32 mm pump with a 160 casing.
How much flow and head can the IHG series deliver?
The published envelope is 1–1500 m³/h of flow with heads from 7 to 150 m. The published model table covers the smaller end from 1.1 m³/h at 8.5 m on the 15-80 up to 8.3 m³/h at 33.2 m on the 32-160 (I); larger sizes are available in the same family.
Where should an inline IHG pump be used?
It suits clearance-rated duties such as urban water supply, high-rise pressure boosting and long-distance water supply, and any installation where a compact footprint and low noise matter more than handling solids.
Can the IHG pump handle chemical or dirty liquids?
The series is published for clear water and liquids whose physical and chemical properties are similar to clear water, so corrosive, abrasive or solids-bearing media need a different pump family.
What is the flow and head range of the IHG vertical inline pump?
The published envelope is 1–1500 m³/h of flow and 7–150 m of head, with the published model table covering the smaller sizes from 15-80 to 32-160 (I).
What medium is the IHG pump designed for?
Clear water and other liquids whose physical and chemical properties are similar to those of clear water; it is used for urban water supply, high-rise buildings and long-distance water supply.
How is the IHG pump installed?
It is a vertical inline pump, so the suction and discharge ports sit on the same centre line and the unit can be mounted directly into a straight pipe run, saving floor space and construction investment.
What are the published advantages of the IHG series?
High efficiency and energy saving through an advanced hydraulic model, a small footprint, low construction investment, low noise and no pollution.
What speed and motor power do the models use?
The smallest models 15-80 and 20-110 run at 2800 r/min with 0.18 kW and 0.37 kW motors, while the larger published models run at 2900 r/min with motors from 0.55 kW to 2.2 kW.
Get a Quote
Send flow, head, temperature and the available installation space.
Request a Quote →💬 WhatsApp NowRelated Products
- ISW Series Inline Centrifugal Pump
- IH Series Stainless Steel Chemical Pump
- AFB Series Chemical Centrifugal Pump
- FSB Horizontal Fluoroplastic Pump
How to Select an IHG Vertical Inline Pump
Quick answer: The IHG is selected from the required flow and head and the space available in the pipe run. The vertical inline layout covers 1–1500 m³/h and 7–150 m with motors from 0.18 to 2500 kW, for clear water and similar liquids between -20 °C and 120 °C.
Selection Data to Send Our Engineers
- Flow rate
- Head / discharge pressure
- Liquid name and properties
- Operating temperature
- Motor voltage and frequency
- Installation space and pipe size
Industry Applications